Abbildung intAct AGM-Power
Symbol: Eignung für Wohnmobile
Symbol: Eignung für Marine
Symbol: Eignung für wind-power plants
Symbol: Eignung für Solar applications
Symbol: Eignung für Bus
Symbol Recycling efficiency 95 %
Symbol Maximum tipping angle 90º
Sealed maintenance-free AGM battery with grid plates | electrolyte absorbed in glass fibre mats | wet charged

intAct AGM-PowerMaintenance-free all-round

Completely sealed maintenance-free and leak-proof, therefore well suited for the interior. Uncomplicated power supply for hobby and leisure-time pursuits and smaller solar applications.

Our recommendation for those looking for an affordable sealed supply battery.

Features

  • Leak-proof

    Because the electrolyte is bound in the glass fibre mat and the battery is tightly sealed and equipped with a safety valve, it is leak-proof.

    Your advantage: This battery is suitable for use on water, e.g. for powering on-board equipment or navigation instruments on boats, or wherever a leak-proof battery is required.

  • Maintenance-free

    Your advantage: You don't need to worry about water level checks and refills.

Characteristics

  • 300 charging cycles according to IEC 254-1.
  • Longer service life than flooded lead-acid battery.
  • Low self-discharge.
  • VRLA battery with gas recombination and safety valves, where refilling is neither possible or necessary.
  • Sealed AGM battery with grid plates.
  • Leak-proof. Can also be installed at an angle, as the electrolyte is absorbed in glass fibre mats and the battery is tightly sealed.
  • Wet charged. Ready to use.
  • Sealed maintenance-free.
Recycling efficiency 95 %
Maximum tipping angle 90º

All types

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
AGM55i1255 AH (c20), 70 AH (c100)24217519001more
product image Supply Battery intAct AGM-Power AGM55

AGM55

Japan-Code:{jpn}

AGM55

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:55 AH (c20), 70 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:242 x 175 x 190 mm
Schema Batteriekasten L02

Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM65i1265 AH (c20), 90 AH (c100)27817519001more
product image Supply Battery intAct AGM-Power AGM65

AGM65

Japan-Code:{jpn}

AGM65

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:65 AH (c20), 90 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM90i1290 AH (c20), 110 AH (c100)35317519001more
product image Supply Battery intAct AGM-Power AGM90

AGM90

Japan-Code:{jpn}

AGM90

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:90 AH (c20), 110 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM100i12100 AH (c20), 120 AH (c100)35817523301more
product image Supply Battery intAct AGM-Power AGM100

AGM100

Japan-Code:{jpn}

AGM100

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:100 AH (c20), 120 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:358 x 175 x 233 mm
Schema Batteriekasten T13

Kasten: T13
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM130i12130 AH (c20), 150 AH (c100)51318922331more
product image Supply Battery intAct AGM-Power AGM130

AGM130

Japan-Code:{jpn}

AGM130

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:130 AH (c20), 150 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 189 x 223 mm
Schema Batteriekasten D04

Kasten: D04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM180i12180 AH (c20), 200 AH (c100)51322322331more
product image Supply Battery intAct AGM-Power AGM180

AGM180

Japan-Code:{jpn}

AGM180

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:180 AH (c20), 200 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Schema Batteriekasten D05

Kasten: D05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM200i12200 AH (c20), 230 AH (c100)51827624231more
product image Supply Battery intAct AGM-Power AGM200

AGM200

Japan-Code:{jpn}

AGM200

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:200 AH (c20), 230 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Schema Batteriekasten D06

Kasten: D06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Selectiva


Battery-friendly high-performance chargers with high overall efficiency.


See product

Battery knowledge

What is an AGM battery?
What is a camper battery?
A supply battery used in motorhomes or campers, colloquially known as a camper battery. Typically, it is charged with stationary charging current at the RV parking lot or via a solar system, because the alternator is not sufficient to provide the necessary …
What types of supply batteries are there?
In order to withstand the stress of cyclic operation for a long time without an excessive drop in performance, the active material in supply batteries is particularly well protected. Depending on the technology used, this is done in different ways: In …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does absolutely maintenance-free mean?
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains …
Why does this battery have such a good current draw?
Due to the AGM technology, this battery absorbs the current particularly well, i.e. it recharges faster than a conventional wet battery and you can charge it with a higher charging current or a more powerful charger, like the ? This characteristic comes …
Safety instructions for handling acid
Battery acid consists partly of sulphuric acid, which is highly corrosive. It attacks your skin, textiles and even metal. Put on protective clothing! So always wear gloves, safety glasses and possibly an acid-proof apron when handling batteries. Choose …
When liquid is lost
Fluid evaporates in batteries during the chemical reaction to generate electricity, more so in a wet battery than in an AGM or GEL battery where the acid is fixed in non-woven or as GEL respectively. Unlike these sealed batteries, the vapor in the sealed …
Removing the starter battery or motorcycle battery
If you want to remove a start-stop battery: inform the vehicle system before removal. First disconnect the negative cable (usually black), also called ground or earth, from the negative terminal of the battery. Then remove the positive cable (usually red) from the positive terminal of the battery.
What is a solar battery?
Utility batteries, which can be used as temporary storage for photovoltaic (PV) or small wind systems, are highly cycle resistant, meaning they can withstand different charging cycles well. In the renewable energy sector, charging cannot be done with …
Check battery externally before charging
If the battery box is damaged or deformed, replace the battery. Clean dirty terminals with a wire brush. Remove oils, fluids or other deposits. For batteries with plugs, check fluid level and refill to MAX with distilled water if necessary.
The difference between low maintenance, maintenance free and absolutely maintenance free.
Low-maintenance, flooded lead-acid batteries lose fluid during normal use. They must be maintained, i.e. the fluid level should be checked regularly and the fluid loss compensated with distilled water if necessary. These batteries usually have vent caps …
What does damage to the battery box indicate?
Damaged battery box If the housing is leaking, cracked or chafed, this indicates destruction by external influences. Tip: Look for a robust design in your next battery. Deformed battery case If the housing is deformed by heat, this indicates a defective …
Causal research for better purchasing decisions
Batteries age and fail. Sometimes it happens faster than you planned. If you know the cause of premature aging, you have a chance to make a more appropriate choice now: A battery that fits your technical requirements, intended use, and individual habits …
Always choose the right battery for the application
When choosing a battery, it basically depends on what it is to be used for. The most important distinction is between starter batteries, including motorcycle batteries, and cyclic batteries such as traction or supply batteries. Starter batteries, including …
What is short circuit and how do I prevent it?
Short-circuiting occurs when the two terminals or plates of a battery are accidentally connected together. This can happen if the separator between the plates is damaged by vibration, for example, or if excessive battery sludge builds up, closing the …

What is a Supply Battery?

Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.

So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.

Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.

Maintenance and Care

Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.

Für welchen Einsatz ist die intAct AGM-Power geeignet?

Symbol WohnmobileWohnmobile
Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge
Symbol MarineMarine
Boats, ships, yachts
Symbol wind-power plantswind-power plants
As a power storage for small to medium-sized wind power plants or wind turbines.
Symbol Solar applicationsSolar applications
Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc.
Symbol BusBus
Bus, Omnibus, Autobus