intAct AGM-PowerMaintenance-free all-round
Completely sealed maintenance-free and leak-proof, therefore well suited for the interior. Uncomplicated power supply for hobby and leisure-time pursuits and smaller solar applications.
Our recommendation for those looking for an affordable sealed supply battery.
Features
Leak-proof
Because the electrolyte is bound in the glass fibre mat and the battery is tightly sealed and equipped with a safety valve, it is leak-proof.
Your advantage: This battery is suitable for use on water, e.g. for powering on-board equipment or navigation instruments on boats, or wherever a leak-proof battery is required.
Maintenance-free
Your advantage: You don't need to worry about water level checks and refills.
Characteristics
- 300 charging cycles according to IEC 254-1.
- Longer service life than flooded lead-acid battery.
- Low self-discharge.
- VRLA battery with gas recombination and safety valves, where refilling is neither possible or necessary.
- Sealed AGM battery with grid plates.
- Leak-proof. Can also be installed at an angle, as the electrolyte is absorbed in glass fibre mats and the battery is tightly sealed.
- Wet charged. Ready to use.
- Sealed maintenance-free.
All types
Battery | Volt | Capacity | CCA | Length mm | Width mm | Height mm | Pos. of terminal | Terminal | |
---|---|---|---|---|---|---|---|---|---|
AGM55i | 12 | 55 AH (c20), 70 AH (c100) | 242 | 175 | 190 | 0 | 1 | more | |
AGM55Japan-Code:{jpn}
AGM55Position of Terminal:0
Volt:12
Terminal:1
Capacity:55 AH (c20), 70 AH (c100)
Base plate:B13
Cold Cranking Ampere:
Size:242 x 175 x 190 mm
Kasten: L02 Where can I buy this battery?
Download datasheet
| |||||||||
AGM65i | 12 | 65 AH (c20), 90 AH (c100) | 278 | 175 | 190 | 0 | 1 | more | |
AGM65Japan-Code:{jpn}
AGM65Position of Terminal:0
Volt:12
Terminal:1
Capacity:65 AH (c20), 90 AH (c100)
Base plate:B13
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Kasten: L03 Where can I buy this battery?
Download datasheet
| |||||||||
AGM90i | 12 | 90 AH (c20), 110 AH (c100) | 353 | 175 | 190 | 0 | 1 | more | |
AGM90Japan-Code:{jpn}
AGM90Position of Terminal:0
Volt:12
Terminal:1
Capacity:90 AH (c20), 110 AH (c100)
Base plate:B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Kasten: L05 Where can I buy this battery?
Download datasheet
| |||||||||
AGM100i | 12 | 100 AH (c20), 120 AH (c100) | 358 | 175 | 233 | 0 | 1 | more | |
AGM100Japan-Code:{jpn}
AGM100Position of Terminal:0
Volt:12
Terminal:1
Capacity:100 AH (c20), 120 AH (c100)
Base plate:B13
Cold Cranking Ampere:
Size:358 x 175 x 233 mm
Kasten: T13 Where can I buy this battery?
Download datasheet
| |||||||||
AGM130i | 12 | 130 AH (c20), 150 AH (c100) | 513 | 189 | 223 | 3 | 1 | more | |
AGM130Japan-Code:{jpn}
AGM130Position of Terminal:3
Volt:12
Terminal:1
Capacity:130 AH (c20), 150 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 189 x 223 mm
Kasten: D04 Where can I buy this battery?
Download datasheet
| |||||||||
AGM180i | 12 | 180 AH (c20), 200 AH (c100) | 513 | 223 | 223 | 3 | 1 | more | |
AGM180Japan-Code:{jpn}
AGM180Position of Terminal:3
Volt:12
Terminal:1
Capacity:180 AH (c20), 200 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Kasten: D05 Where can I buy this battery?
Download datasheet
| |||||||||
AGM200i | 12 | 200 AH (c20), 230 AH (c100) | 518 | 276 | 242 | 3 | 1 | more | |
AGM200Japan-Code:{jpn}
AGM200Position of Terminal:3
Volt:12
Terminal:1
Capacity:200 AH (c20), 230 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Kasten: D06 Where can I buy this battery?
Download datasheet
|
Accessories
Charger
Fronius Selectiva
Battery-friendly high-performance chargers with high overall efficiency.
See product
What is a Supply Battery?
Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.
So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.
Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.
Maintenance and Care
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.
Für welchen Einsatz ist die intAct AGM-Power geeignet?
Wohnmobile Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge | |
Marine Boats, ships, yachts | |
wind-power plants As a power storage for small to medium-sized wind power plants or wind turbines. | |
Solar applications Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc. | |
Bus Bus, Omnibus, Autobus |