Abbildung intAct US-Power
Symbol: Eignung für car
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 45º
Maintenance-free calcium battery (Ca/Ca) with expanded metal grids | wet charged

intAct US-PowerFor American vehicles

State-of-the-art high-performance batteries, where dimensions and end-pole types are matched to the requirements of U.S. vehicles.

Our recommendation if installation dimensions and connections require a special battery.

Features

  • install

    Your advantage: Fits exactly into your US vehicle with the correct dimensions.

  • Connect quickly

    Your advantage: Can be easily connected to the cables of common US models using the US front terminal with internal thread or A-cone terminal.

Characteristics

  • Very high cold start performance.
  • Minimal self-discharge.
  • 2 versions: U.S. front terminal with inside thread
    (Types 56010 and 57010) and A-cone terminal according to DIN 60095 T2 (Type 58010).
  • Approval for charging voltages up to 14.8 volts.
  • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
Start-Stop not
OEM quality
Maximum tipping angle 45º

All Types

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
56010GUGi1260 AH (c20)600 A (EN)2301791861USmore
product image Starter Battery intAct US-Power 56010GUG

56010GUG

Japan-Code:{jpn}

56010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:60 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:600 A (EN)
Size:230 x 179 x 186 mm
Schema Batteriekasten G75

Kasten: G75
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
57010GUGi1270 AH (c20)670 A (EN)2601791861USmore
product image Starter Battery intAct US-Power 57010GUG

57010GUG

Japan-Code:{jpn}

57010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:70 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:670 A (EN)
Size:260 x 179 x 186 mm
Schema Batteriekasten G78

Kasten: G78
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
58010GUGi1285 AH (c20)800 A (EN)29518919211more
product image Starter Battery intAct US-Power 58010GUG

58010GUG

Japan-Code:{jpn}

58010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:85 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:800 A (EN)
Size:295 x 189 x 192 mm
Schema Batteriekasten G65

Kasten: G65
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
Always choose the right battery for the application
When choosing a battery, it basically depends on what it is to be used for. The most important distinction is between starter batteries, including motorcycle batteries, and cyclic batteries such as traction or supply batteries. Starter batteries, including …
Care should be taken when handling batteries
Chemical processes take place in batteries. They are influenced by external circumstances such as temperature or humidity. That is why it is worth taking care. During use, storage, installation and transport. For your own protection and for the protection …
Charge filled and charged battery before installation.
A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life. Even factory-filled and charged batteries can lose charge during storage. We recommend that you also …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What do discoloured plugs mean?
A brown-reddish discoloration of the plugs indicates an overcharging of the battery and a fault in the charging system. Tip: Your workshop can check whether your charge controller is working properly. Tip: Check the function and characteristics of your …
Removing the starter battery or motorcycle battery
If you want to remove a start-stop battery: inform the vehicle system before removal. First disconnect the negative cable (usually black), also called ground or earth, from the negative terminal of the battery. Then remove the positive cable (usually red) from the positive terminal of the battery.
Causal research for better purchasing decisions
Batteries age and fail. Sometimes it happens faster than you planned. If you know the cause of premature aging, you have a chance to make a more appropriate choice now: A battery that fits your technical requirements, intended use, and individual habits …
Always choose a battery that suits your individual requirements
Each battery technology has particular strengths, but also weaknesses. Depending on the requirements your battery has to meet in the respective application, or which properties you want, some battery technologies are more suitable or less suitable. It is important to weigh up the properties.
What does low maintenance mean?
Low-maintenance batteries can be recognised by the removable sealing plugs on the top, the vent hose and the white or transparent housing. In these batteries, the electrolyte is in liquid form, i.e. it is not bound as GEL or in fleece. They are not sealed …
Charge lithium battery before installation
A battery that is not fully charged when installed will not reach its full performance in the future and will have a significantly shortened service life. Lithium batteries can also lose charge during storage. We recommend that you also fully charge them …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct US-Power suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van