Abbildung intAct Marine-Power
Symbol: Eignung für Marine
Symbol: Eignung für wind-power plants
Symbol: Eignung für Solar applications
Symbol Recycling efficiency 95 %
Symbol mounting angle 0º
Closed lead-acid battery with reinforced grid plates | low maintenance

intAct Marine-PowerCost-conscious marine battery


Robust technology with good capacity absorption and high capacity reserves for small supply tasks as well as good high current characteristics in light cyclic use.
Our recommendation for small dual-purpose applications on boats.

Features

  • Price-conscious Dual-Purpose Battery

    Your advantage: Inexpensive storage and drive battery for operating lights, cooling, GPS as well as light winches on boats.

  • Easy to install

    Your advantage: Unproblematic battery replacement thanks to standardized battery boxes in common sizes.

  • Low maintenance

    Here the plugs can be removed and you can easily check. In addition, the truck sizes can be upgraded with a water filling system.
    Your advantage: easy prevention and maintenance, longer maintenance cycles.

Characteristics

  • Light cyclic use. 300 cycles according to IEC 254-1.
  • Reinforced grid plates in special insulation with high mass utilization for maximum reserve capacity.
  • Robust, technically simple, mature technology for applications with low, reliable power requirements.
  • Ideal for stand-by operation.
  • Excellent price/performance ratio. Durable, safe and reliable.
  • Partial base plate for secure footing.
  • Wet, sealed block battery. Low maintenance.
  • Can be equipped with water refill system to extend service intervals.
  • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
mounting angle 0º

All types

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
MP75i1260 AH (c5), 75 AH (c20), 90 AH (c100)27817519001more
product image Supply Battery intAct Marine-Power MP75

MP75

Japan-Code:{jpn}

MP75

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:60 AH (c5), 75 AH (c20), 90 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP100i1280 AH (c5), 100 AH (c20), 110 AH (c100)35317519001more
product image Supply Battery intAct Marine-Power MP100

MP100

Japan-Code:{jpn}

MP100

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:80 AH (c5), 100 AH (c20), 110 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP114i1295 (c5), 114 AH (c20), 128 AH (c100)33017224211more
product image Supply Battery intAct Marine-Power MP114

MP114

Japan-Code:{jpn}

MP114

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:95 (c5), 114 AH (c20), 128 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:330 x 172 x 242 mm
Schema Batteriekasten G31

Kasten: G31
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP120i12115 AH (c5), 125 AH (c20), 140 AH (c100)51318922331more
product image Supply Battery intAct Marine-Power MP120

MP120

Japan-Code:{jpn}

MP120

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:115 AH (c5), 125 AH (c20), 140 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 189 x 223 mm
Schema Batteriekasten D04

Kasten: D04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP180i12135 (c5), 180 AH (c20), 200 AH (c100)51322322331more
product image Supply Battery intAct Marine-Power MP180

MP180

Japan-Code:{jpn}

MP180

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:135 (c5), 180 AH (c20), 200 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Schema Batteriekasten D05

Kasten: D05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP225i12180 AH (c5), 225 AH (c20), 250 AH (c100)51827624231more
product image Supply Battery intAct Marine-Power MP225

MP225

Japan-Code:{jpn}

MP225

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:180 AH (c5), 225 AH (c20), 250 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Schema Batteriekasten D06

Kasten: D06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

DEFA workshop chargers


Powerful workshop charger.
Protects onboard electronics and battery while working on the vehicle.


See product

Battery knowledge

What waterproof brings
Ideally, batteries should be kept dry. Even slight moisture can promote leakage currents. If you've noticed condensation on your battery frequently in the past, such as with temperature fluctuations, or water can get to your battery, it's worth considering …
Filling a dry pre-charged battery
Dry pre-charged batteries must be filled with battery acid and charged before installation.
Removing the starter battery or motorcycle battery
If you want to remove a start-stop battery: inform the vehicle system before removal. First disconnect the negative cable (usually black), also called ground or earth, from the negative terminal of the battery. Then remove the positive cable (usually red) from the positive terminal of the battery.
What is a solar battery?
Utility batteries, which can be used as temporary storage for photovoltaic (PV) or small wind systems, are highly cycle resistant, meaning they can withstand different charging cycles well. In the renewable energy sector, charging cannot be done with …
The order of disconnection and connection
The negative terminal is connected to the body, hence the name grounding. If you accidentally touch the positive terminal and the body at the same time when the negative terminal is connected, e.g. with a metallic tool, a short circuit could occur that …
Seasonal use of drive or supply battery
Many vehicles, devices or machines are only used seasonally or on certain occasions. Ideally, your battery should be ready whenever you need it. That's why we recommend always storing batteries fully charged, at approx. 15 to 18° C and in a dry place, …
Safety instructions for handling acid
Battery acid consists partly of sulphuric acid, which is highly corrosive. It attacks your skin, textiles and even metal. Put on protective clothing! So always wear gloves, safety glasses and possibly an acid-proof apron when handling batteries. Choose …
What does maintenance-free mean?
In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do …
Time for recovery
Before the winter or summer break, it is best to remove the battery or at least disconnect it and store it in a cool (ideally at 10 to 15 °C) and dry place. Charge every 4 to 6 weeks for 24 to 48 hours with a suitable charger. Check the state of charge …
Always choose the right battery for the application
When choosing a battery, it basically depends on what it is to be used for. The most important distinction is between starter batteries, including motorcycle batteries, and cyclic batteries such as traction or supply batteries. Starter batteries, including …

What is a Supply Battery?

Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.

So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.

Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.

Für welchen Einsatz ist die intAct Marine-Power geeignet?

Symbol MarineMarine
Boats, ships, yachts
Symbol wind-power plantswind-power plants
As a power storage for small to medium-sized wind power plants or wind turbines.
Symbol Solar applicationsSolar applications
Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc.