Abbildung intAct Marine-Power
Symbol: Eignung für Marine
Symbol: Eignung für wind-power plants
Symbol: Eignung für Solar applications
Symbol Recycling efficiency 95 %
Symbol mounting angle 0º
Closed lead-acid battery with reinforced grid plates | low maintenance

intAct Marine-PowerCost-conscious marine battery


Robust technology with good capacity absorption and high capacity reserves for small supply tasks as well as good high current characteristics in light cyclic use.
Our recommendation for small dual-purpose applications on boats.

Features

  • Price-conscious Dual-Purpose Battery

    Your advantage: Inexpensive storage and drive battery for operating lights, cooling, GPS as well as light winches on boats.

  • Easy to install

    Your advantage: Unproblematic battery replacement thanks to standardized battery boxes in common sizes.

  • Low maintenance

    Here the plugs can be removed and you can easily check. In addition, the truck sizes can be upgraded with a water filling system.
    Your advantage: easy prevention and maintenance, longer maintenance cycles.

Characteristics

  • Light cyclic use. 300 cycles according to IEC 254-1.
  • Reinforced grid plates in special insulation with high mass utilization for maximum reserve capacity.
  • Robust, technically simple, mature technology for applications with low, reliable power requirements.
  • Ideal for stand-by operation.
  • Excellent price/performance ratio. Durable, safe and reliable.
  • Partial base plate for secure footing.
  • Wet, sealed block battery. Low maintenance.
  • Can be equipped with water refill system to extend service intervals.
  • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
mounting angle 0º

All types

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
MP75i1260 AH (c5), 75 AH (c20), 90 AH (c100)27817519001more
product image Supply Battery intAct Marine-Power MP75

MP75

Japan-Code:{jpn}

MP75

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:60 AH (c5), 75 AH (c20), 90 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP100i1280 AH (c5), 100 AH (c20), 110 AH (c100)35317519001more
product image Supply Battery intAct Marine-Power MP100

MP100

Japan-Code:{jpn}

MP100

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:80 AH (c5), 100 AH (c20), 110 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP114i1295 (c5), 114 AH (c20), 128 AH (c100)33017224211more
product image Supply Battery intAct Marine-Power MP114

MP114

Japan-Code:{jpn}

MP114

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:95 (c5), 114 AH (c20), 128 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:330 x 172 x 242 mm
Schema Batteriekasten G31

Kasten: G31
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP120i12115 AH (c5), 125 AH (c20), 140 AH (c100)51318922331more
product image Supply Battery intAct Marine-Power MP120

MP120

Japan-Code:{jpn}

MP120

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:115 AH (c5), 125 AH (c20), 140 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 189 x 223 mm
Schema Batteriekasten D04

Kasten: D04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP180i12135 (c5), 180 AH (c20), 200 AH (c100)51322322331more
product image Supply Battery intAct Marine-Power MP180

MP180

Japan-Code:{jpn}

MP180

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:135 (c5), 180 AH (c20), 200 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Schema Batteriekasten D05

Kasten: D05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
MP225i12180 AH (c5), 225 AH (c20), 250 AH (c100)51827624231more
product image Supply Battery intAct Marine-Power MP225

MP225

Japan-Code:{jpn}

MP225

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:180 AH (c5), 225 AH (c20), 250 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Schema Batteriekasten D06

Kasten: D06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

DEFA workshop chargers


Powerful workshop charger.
Protects onboard electronics and battery while working on the vehicle.


See product

Battery knowledge

When liquid is lost
Fluid evaporates in batteries during the chemical reaction to generate electricity, more so in a wet battery than in an AGM or GEL battery where the acid is fixed in non-woven or as GEL respectively. Unlike these sealed batteries, the vapor in the sealed …
AGM and gel supply batteries
Deep-cycle batteries in AGM or gel design can be used in a variety of applications. They are suitable as supply batteries in the areas of marine, solar and camping, because the electrolyte is bound in gel or fleece (Absorbent Glass Mat), which makes the …
Batteries without vent hose
Only conventional, wet batteries need a vent hose, because they gas strongly during operation. The resulting steam can escape through the openings in the plugs. To prevent the vapour from damaging the vehicle, conventional batteries are vented to the …
Why does this battery have such a good current draw?
Due to the AGM technology, this battery absorbs the current particularly well, i.e. it recharges faster than a conventional wet battery and you can charge it with a higher charging current or a more powerful charger, like the ? This characteristic comes …
Lithium supply batteries
The capacity and performance of lithium iron phosphate batteries are very high compared to other batteries of the same box size. They have an extremely long life expectancy, low self-discharge and can tolerate the highest charging currents. To fully charge …
Always choose a battery that suits your individual requirements
Each battery technology has particular strengths, but also weaknesses. Depending on the requirements your battery has to meet in the respective application, or which properties you want, some battery technologies are more suitable or less suitable. It is important to weigh up the properties.
Every battery ages
With each charge/discharge process (cycle), active material is inevitably lost and the battery's performance declines. Once it has fallen to the point where it can no longer fulfil its purpose - e.g. start the vehicle, supply the consumers or drive the …
Avoid corrosion
The plates in a battery will corrode if they are not completely covered by battery water. Reasons for corrosion Sealing damaged before filling in dry pre-charged batteries Closed, low-maintenance batteries such as the intAct Bike-Power Classic are dry …
Always select a battery that matches the charging behavior
Starter batteries, including motorcycle batteries, are charged by the alternator while driving. The charge takes place over a longer period of time with low current. Starter batteries are designed for this charging behaviour. Some starter batteries …
Time for recovery
Before the winter or summer break, it is best to remove the battery or at least disconnect it and store it in a cool (ideally at 10 to 15 °C) and dry place. Charge every 4 to 6 weeks for 24 to 48 hours with a suitable charger. Check the state of charge …

What is a Supply Battery?

Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.

So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.

Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.

Für welchen Einsatz ist die intAct Marine-Power geeignet?

Symbol MarineMarine
Boats, ships, yachts
Symbol wind-power plantswind-power plants
As a power storage for small to medium-sized wind power plants or wind turbines.
Symbol Solar applicationsSolar applications
Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc.