Trojan Deep CycleMore working hours, more flexibility
The robust battery for many deep discharges and varying charging currents. Perfect as a power-supply for basic consumers in the recreational sector or as a small to medium-sized intermediate storage for solar or wind energy.
Our recommendation for those who want to run more than a small garden shed or other more demanding hobby applications.
Features
Economical flooded battery: Price tip
Your advantage: With this high-quality flooded battery, you can maintain a reasonable power supply at low cost.
Expandable
Your advantage: By combining several batteries you have the possibility to install large capacities.
Very cycle resistant
This battery brings in all variations significantly more cycles than the other grid battery types, both wet and AGM and GEL batteries.
Your advantage: a very long-lasting battery.
Characteristics
- Very high life expectancy. 700 cycles according to IEC 254-1 for heavy cyclic use.
- Proven technology for low power applications.
- Robust design with reinforced separators.
- 6-volt, 8-volt and 12-volt versions.
- Reinforced grid plates with high-performaning active-material for increased reliability.
- Flooded block battery. Low maintenance. Durable, safe and reliable
- With a wide range of end-pole types for a wide range of requirements.
All types
Trojan Deep Cycle
Battery | Volt | Capacity | CCA | Length mm | Width mm | Height mm | Pos. of terminal | Terminal | |
---|---|---|---|---|---|---|---|---|---|
T105PLUSi | 6 | 185 AH (c5), 225 AH (c20), 250 AH (c100) | 262 | 181 | 281 | 0 | 1 | more | |
T105PLUSJapan-Code:{jpn}
T105PLUSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:185 AH (c5), 225 AH (c20), 250 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 281 mm
Kasten: T02 Where can I buy this battery?
Download datasheet
| |||||||||
T105i | 6 | 185 AH (c5), 225 AH (c20), 250 AH (c100) | 262 | 181 | 281 | 0 | 1 | more | |
T105Japan-Code:{jpn}
T105Position of Terminal:0
Volt:6
Terminal:1
Capacity:185 AH (c5), 225 AH (c20), 250 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 281 mm
Kasten: T02 Where can I buy this battery?
Download datasheet
| |||||||||
TE35i | 6 | 201 AH (c5), 245 AH (c20), 270 AH (c100) | 244 | 191 | 269 | 0 | 1 | more | |
TE35Japan-Code:{jpn}
TE35Position of Terminal:0
Volt:6
Terminal:1
Capacity:201 AH (c5), 245 AH (c20), 270 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:244 x 191 x 269 mm
Kasten: TE35 Where can I buy this battery?
Download datasheet
| |||||||||
T145i | 6 | 215 AH (c5), 260 AH (c20), 287 AH (c100) | 262 | 181 | 302 | 0 | 1 | more | |
T145Japan-Code:{jpn}
T145Position of Terminal:0
Volt:6
Terminal:1
Capacity:215 AH (c5), 260 AH (c20), 287 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 302 mm
Kasten: T145 Where can I buy this battery?
Download datasheet
| |||||||||
T145PLUSi | 6 | 215 AH (c5), 260 AH (c20), 287 AH (c100) | 262 | 181 | 302 | 0 | 1 | more | |
T145PLUSJapan-Code:{jpn}
T145PLUSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:215 AH (c5), 260 AH (c20), 287 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 302 mm
Kasten: T145PLUS Where can I buy this battery?
Download datasheet
| |||||||||
J305E-ACi | 6 | 250 AH (c5), 305 AH (c20), 339 AH (c100) | 312 | 174 | 366 | 0 | 1 | more | |
J305E-ACJapan-Code:{jpn}
J305E-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:250 AH (c5), 305 AH (c20), 339 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:312 x 174 x 366 mm
Kasten: J305E-AC Where can I buy this battery?
Download datasheet
| |||||||||
J305G-ACi | 6 | 258 AH (c5), 315 AH (c20), 350 AH (c100) | 312 | 174 | 366 | 0 | 1 | more | |
J305G-ACJapan-Code:{jpn}
J305G-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:258 AH (c5), 315 AH (c20), 350 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:312 x 174 x 366 mm
Kasten: J305G-AC Where can I buy this battery?
Download datasheet
| |||||||||
J305P-ACi | 6 | 271 AH (c5), 330 AH (c20), 367 AH (c100) | 296 | 176 | 366 | 0 | 1 | more | |
J305P-ACJapan-Code:{jpn}
J305P-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:271 AH (c5), 330 AH (c20), 367 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:296 x 176 x 366 mm
Kasten: J305P-AC Where can I buy this battery?
Download datasheet
| |||||||||
J305H-ACi | 6 | 295 AH (c5), 360 AH (c20), 400 AH (c100) | 296 | 176 | 366 | 0 | 1 | more | |
J305H-ACJapan-Code:{jpn}
J305H-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:295 AH (c5), 360 AH (c20), 400 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:296 x 176 x 366 mm
Kasten: J305H-AC Where can I buy this battery?
Download datasheet
| |||||||||
L16G-ACi | 6 | 320 AH (c5), 390 AH (c20), 433 AH (c100) | 311 | 174 | 417 | 0 | 1 | more | |
L16G-ACJapan-Code:{jpn}
L16G-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:320 AH (c5), 390 AH (c20), 433 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:311 x 174 x 417 mm
Kasten: L16G-AC Where can I buy this battery?
Download datasheet
| |||||||||
L16P-ACi | 6 | 344 AH (c5), 420 AH (c20), 467 AH (c100) | 296 | 176 | 425 | 0 | 1 | more | |
L16P-ACJapan-Code:{jpn}
L16P-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:344 AH (c5), 420 AH (c20), 467 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:296 x 176 x 425 mm
Kasten: L16P-AC Where can I buy this battery?
Download datasheet
| |||||||||
L16H-ACi | 6 | 357 AH (c5), 435 AH (c20), 483 AH (c100) | 296 | 176 | 425 | 0 | 1 | more | |
L16H-ACJapan-Code:{jpn}
L16H-ACPosition of Terminal:0
Volt:6
Terminal:1
Capacity:357 AH (c5), 435 AH (c20), 483 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:296 x 176 x 425 mm
Kasten: L16H-AC Where can I buy this battery?
Download datasheet
| |||||||||
T875i | 8 | 145 AH (c5), 170 AH (c20), 189 AH (c100) | 259 | 179 | 283 | 0 | 1 | more | |
T875Japan-Code:{jpn}
T875Position of Terminal:0
Volt:8
Terminal:1
Capacity:145 AH (c5), 170 AH (c20), 189 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:259 x 179 x 283 mm
Kasten: T875 Where can I buy this battery?
Download datasheet
| |||||||||
T890i | 8 | 155 AH (c5), 190 AH (c20), 211 AH (c100) | 259 | 179 | 283 | 0 | 1 | more | |
T890Japan-Code:{jpn}
T890Position of Terminal:0
Volt:8
Terminal:1
Capacity:155 AH (c5), 190 AH (c20), 211 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:259 x 179 x 283 mm
Kasten: T890 Where can I buy this battery?
Download datasheet
| |||||||||
27TMXi | 12 | 85AH (c5), 105AH (c20), 117AH (c100) | 323 | 168 | 235 | 0 | AP | more | |
27TMXJapan-Code:{jpn}
27TMXPosition of Terminal:0
Volt:12
Terminal:AP
Capacity:85AH (c5), 105AH (c20), 117AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:323 x 168 x 235 mm
Kasten: 27TMX Where can I buy this battery?
Download datasheet
| |||||||||
31XHSi | 12 | 105 AH (c5), 130 AH (c20), 144 AH (c100) | 329 | 171 | 243 | 0 | 0 | more | |
31XHSJapan-Code:{jpn}
31XHSPosition of Terminal:0
Volt:12
Terminal:0
Capacity:105 AH (c5), 130 AH (c20), 144 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:329 x 171 x 243 mm
Kasten: 31XHS Where can I buy this battery?
Download datasheet
| |||||||||
T1260PLUSi | 12 | 113 AH (c5), 140 AH (c20), 155 AH (c100) | 329 | 181 | 272 | 0 | 1 | more | |
T1260PLUSJapan-Code:{jpn}
T1260PLUSPosition of Terminal:0
Volt:12
Terminal:1
Capacity:113 AH (c5), 140 AH (c20), 155 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:329 x 181 x 272 mm
Kasten: T1260PLUS Where can I buy this battery?
Download datasheet
| |||||||||
T1275PLUSi | 12 | 120 AH (c5), 150 AH (c20), 166 AH (c100) | 329 | 181 | 272 | 0 | 1 | more | |
T1275PLUSJapan-Code:{jpn}
T1275PLUSPosition of Terminal:0
Volt:12
Terminal:1
Capacity:120 AH (c5), 150 AH (c20), 166 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:329 x 181 x 272 mm
Kasten: T1275PLUS Where can I buy this battery?
Download datasheet
| |||||||||
T105-AGMi | 6 | 171 AH (c5), 217 AH (c20), 230 AH (c100) | 262 | 181 | 281 | 0 | 1 | more | |
T105-AGMJapan-Code:{jpn}
T105-AGMPosition of Terminal:0
Volt:6
Terminal:1
Capacity:171 AH (c5), 217 AH (c20), 230 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 281 mm
Kasten: T02 Where can I buy this battery?
Download datasheet
| |||||||||
T875-AGMi | 8 | 130 AH (c5), 160 AH (c20), 170 AH (c100) | 262 | 179 | 273 | 0 | 0 | more | |
T875-AGMJapan-Code:{jpn}
T875-AGMPosition of Terminal:0
Volt:8
Terminal:0
Capacity:130 AH (c5), 160 AH (c20), 170 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:262 x 179 x 273 mm
Kasten: T875-AGM Where can I buy this battery?
Download datasheet
|
Rolls Deep Cycle
Battery | Volt | Capacity | CCA | Length mm | Width mm | Height mm | Pos. of terminal | Terminal | |
---|---|---|---|---|---|---|---|---|---|
J305G-ROLLSi | 6 | 253 AH (c5), 320 AH (c20), 410 AH (c100) | k.A. A (EN) | 311 | 181 | 362 | 0 | 1 | more |
J305G-ROLLSJapan-Code:{jpn}
J305G-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:253 AH (c5), 320 AH (c20), 410 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:311 x 181 x 362 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
T105-ROLLSi | 6 | 186 AH (c5), 235 AH (c20), 301 AH (c100) | k.A. A (EN) | 262 | 181 | 281 | 0 | 1 | more |
T105-ROLLSJapan-Code:{jpn}
T105-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:186 AH (c5), 235 AH (c20), 301 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:262 x 181 x 281 mm
Kasten: T02 Where can I buy this battery?
Download datasheet
| |||||||||
TE35-ROLLSi | 6 | 198 AH (c5), 250 AH (c20), 320 AH (c100) | k.A. A (EN) | 244 | 191 | 269 | 0 | 1 | more |
TE35-ROLLSJapan-Code:{jpn}
TE35-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:198 AH (c5), 250 AH (c20), 320 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:244 x 191 x 269 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
J305PH-ROLLSi | 6 | 284 AH (c5), 360 AH (c20), 461 AH (c100) | k.A. A (EN) | 311 | 181 | 362 | 0 | 1 | more |
J305PH-ROLLSJapan-Code:{jpn}
J305PH-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:284 AH (c5), 360 AH (c20), 461 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:311 x 181 x 362 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
L16E-ROLLSi | 6 | 300 AH (c5), 375 AH (c20), 431 AH (c100) | k.A. A (EN) | 318 | 181 | 425 | 0 | 1 | more |
L16E-ROLLSJapan-Code:{jpn}
L16E-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:300 AH (c5), 375 AH (c20), 431 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:318 x 181 x 425 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
L16PH-ROLLSi | 6 | 340 AH (c5), 425 AH (c20), 489 AH (c100) | k.A. A (EN) | 318 | 181 | 425 | 0 | 1 | more |
L16PH-ROLLSJapan-Code:{jpn}
L16PH-ROLLSPosition of Terminal:0
Volt:6
Terminal:1
Capacity:340 AH (c5), 425 AH (c20), 489 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:318 x 181 x 425 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
30XHS-ROLLSi | 12 | 98 AH (c5), 130 AH (c20), 173 AH (c100) | k.A. A (EN) | 330 | 171 | 241 | 1 | 1 | more |
30XHS-ROLLSJapan-Code:{jpn}
30XHS-ROLLSPosition of Terminal:1
Volt:12
Terminal:1
Capacity:98 AH (c5), 130 AH (c20), 173 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:330 x 171 x 241 mm
(_keine_s1) Where can I buy this battery?
Download datasheet
|
Rocket Deep Cycle
Battery | Volt | Capacity | CCA | Length mm | Width mm | Height mm | Pos. of terminal | Terminal | |
---|---|---|---|---|---|---|---|---|---|
T105-ROCKETi | 6 | 185 AH (c5), 225 AH (c20), 275 AH (c100) | k.A. A (EN) | 262 | 181 | 281 | 0 | 1 | more |
T105-ROCKETJapan-Code:{jpn}
T105-ROCKETPosition of Terminal:0
Volt:6
Terminal:1
Capacity:185 AH (c5), 225 AH (c20), 275 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:262 x 181 x 281 mm
Kasten: T02 Where can I buy this battery?
Download datasheet
| |||||||||
T125-ROCKETi | 6 | 195 AH (c5), 240 AH (c20), 266 AH (c100) | k.A. A (EN) | 259 | 179 | 278 | 0 | 1 | more |
T125-ROCKETJapan-Code:{jpn}
T125-ROCKETPosition of Terminal:0
Volt:6
Terminal:1
Capacity:195 AH (c5), 240 AH (c20), 266 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:259 x 179 x 278 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
T145-ROCKETi | 6 | 215 AH (c5), 260 AH (c20), 287 AH (c100) | k.A. A (EN) | 259 | 179 | 297 | 0 | 1 | more |
T145-ROCKETJapan-Code:{jpn}
T145-ROCKETPosition of Terminal:0
Volt:6
Terminal:1
Capacity:215 AH (c5), 260 AH (c20), 287 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:259 x 179 x 297 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
T875-ROCKETi | 8 | 145 AH (c5), 170 AH (c20), 189 AH (c100) | k.A. A (EN) | 262 | 181 | 278 | 0 | 1 | more |
T875-ROCKETJapan-Code:{jpn}
T875-ROCKETPosition of Terminal:0
Volt:8
Terminal:1
Capacity:145 AH (c5), 170 AH (c20), 189 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:262 x 181 x 278 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
T890-ROCKETi | 8 | 155 AH (c5), 190 AH (c20), 211 AH (c100) | k.A. A (EN) | 262 | 181 | 278 | 0 | 1 | more |
T890-ROCKETJapan-Code:{jpn}
T890-ROCKETPosition of Terminal:0
Volt:8
Terminal:1
Capacity:155 AH (c5), 190 AH (c20), 211 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:262 x 181 x 278 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
| |||||||||
T1275-ROCKETi | 12 | 120 AH (c5), 150 AH (c20), 159 AH (c100) | k.A. A (EN) | 329 | 181 | 278 | 0 | 1 | more |
T1275-ROCKETJapan-Code:{jpn}
T1275-ROCKETPosition of Terminal:0
Volt:12
Terminal:1
Capacity:120 AH (c5), 150 AH (c20), 159 AH (c100)
Base plate:none
Cold Cranking Ampere:k.A. A (EN)
Size:329 x 181 x 278 mm
(_keine_s0) Where can I buy this battery?
Download datasheet
|
Accessories
Charger
Fronius Selectiva
Battery-friendly high-performance chargers with high overall efficiency.
See product
What is a Supply Battery?
Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.
So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.
Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.
Commissioning
Dry pre-charged batteries must be filled with battery acid and charged before installation.
Maintenance and Care
Low-maintenance batteries can be recognised by the removable sealing plugs on the top, the vent hose and the white or transparent housing. In these batteries, the electrolyte is in liquid form, i.e. it is not bound as GEL or in fleece. They are not sealed at the factory, but are activated by the addition of battery acid prior to installation. During normal operation they lose liquid.
To compensate for the loss of fluid promptly and to avoid damage to the battery, we recommend checking the fluid level every 3 months and, if necessary, refilling the battery with distilled water up to the mark (MAX).
Tip: In case of excessive water consumption:
- Check battery box for leakage.
- Have the function of the charge controller checked by a specialist.
Für welchen Einsatz ist die Trojan Deep Cycle geeignet?
Wohnmobile Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge | |
Marine Boats, ships, yachts | |
wind-power plants As a power storage for small to medium-sized wind power plants or wind turbines. | |
Solar applications Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc. |