intAct BackUp-PowerSupport for the starter battery
Supplies consumers in certain types of vehicles and keeps them charged during the start-up, thus protecting the electronics.
Our recommendation as a reliable alternative to the original installed back-up battery.
Features
As backup
for vehicles in which an additional battery is installed
Your benefit: Low cost alternative to the original backup battery.Supplies consumers
Keeps consumers energized during the starting process.
Your advantage: Prevents undervoltage and thus protects the electronics.
Support for main battery
Your advantage: By taking over supply functions, it protects the starter battery from deep discharge.
Characteristics
- Increased cold start performance.
- Longer life expectancy. Three times more cycle resistant than conventional starter batteries.
- Wet charged. Ready to use.
- Sealed valve-regulated battery (VRLA) with gas recombination.
- Sealed maintenance-free and leak-proof.
- Electrolyte absorbed in glass fibre mat.
- Lead-calcium alloy grid plates.
All Types
Battery | Volt | Capacity | CCA | Length mm | Width mm | Height mm | Pos. of terminal | Terminal | |
---|---|---|---|---|---|---|---|---|---|
BU01.2i | 12 | 1.2 AH (c20) | 18 A (EN) | 97 | 43 | 58 | 4 | S-4.8 | more |
BU01.2Japan-Code:{jpn}
BU01.2Position of Terminal:4
Volt:12
Terminal:S-4.8
Capacity:1.2 AH (c20)
Base plate:none
Cold Cranking Ampere:18 A (EN)
Size:97 x 43 x 58 mm
Kasten: I01 Where can I buy this battery?
Download datasheet
| |||||||||
BU09i | 12 | 9 AH (c20) | 120 A (EN) | 150 | 87 | 105 | 1 | screw terminal | more |
BU09Japan-Code:{jpn}
BU09Position of Terminal:1
Volt:12
Terminal:screw terminal
Capacity:9 AH (c20)
Base plate:none
Cold Cranking Ampere:120 A (EN)
Size:150 x 87 x 105 mm
Kasten: M47 Where can I buy this battery?
Download datasheet
| |||||||||
BU11i | 12 | 11 AH (c20) | 150 A (EN) | 150 | 87 | 132 | 1 | screw terminal | more |
BU11Japan-Code:{jpn}
BU11Position of Terminal:1
Volt:12
Terminal:screw terminal
Capacity:11 AH (c20)
Base plate:none
Cold Cranking Ampere:150 A (EN)
Size:150 x 87 x 132 mm
Kasten: M48 Where can I buy this battery?
Download datasheet
| |||||||||
BU12i | 12 | 12 AH (c20) | 200 A (EN) | 150 | 87 | 145 | 1 | screw terminal | more |
BU12Japan-Code:{jpn}
BU12Position of Terminal:1
Volt:12
Terminal:screw terminal
Capacity:12 AH (c20)
Base plate:none
Cold Cranking Ampere:200 A (EN)
Size:150 x 87 x 145 mm
Kasten: M49 Where can I buy this battery?
Download datasheet
| |||||||||
BU14i | 12 | 14 AH (c20) | 80 A (EN) | 151 | 98 | 101 | 3 | screw terminal | more |
BU14Japan-Code:{jpn}
BU14Position of Terminal:3
Volt:12
Terminal:screw terminal
Capacity:14 AH (c20)
Base plate:none
Cold Cranking Ampere:80 A (EN)
Size:151 x 98 x 101 mm
Kasten: I04 Where can I buy this battery?
Download datasheet
| |||||||||
BU15i | 12 | 15 AH (c20) | 200 A (EN) | 150 | 87 | 145 | 1 | 3 | more |
BU15Japan-Code:{jpn}
BU15Position of Terminal:1
Volt:12
Terminal:3
Capacity:15 AH (c20)
Base plate:none
Cold Cranking Ampere:200 A (EN)
Size:150 x 87 x 145 mm
Kasten: M63 Where can I buy this battery?
Download datasheet
| |||||||||
BU30i | 12 | 30 Ah (c20) | keiner | 197 | 132 | 186 | 0 | 1 | more |
BU30Japan-Code:{jpn}
BU30Position of Terminal:0
Volt:12
Terminal:1
Capacity:30 Ah (c20)
Base plate:none
Cold Cranking Ampere:keiner
Size:197 x 132 x 186 mm
(m66_keine_s0) Where can I buy this battery?
Download datasheet
|
Accessories
Charger
Fronius Acctiva
Charge starter batteries professionally and supply consumers and on-board electronics.
See product
What is a starter battery?
A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.
Commissioning
A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.
Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.
You can find out how to do this in our step-by-step guide to charging your battery.
Maintenance and Care
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.
For which applications is the intAct BackUp-Power suitable?
car car, passenger car, cars, automobiles, vans, panel van |