Abbildung intAct Start-Stop-Power AGM
Symbol: Eignung für car
Symbol: Eignung für Wohnmobile
Symbol: Eignung für Marine
Symbol: Eignung für hybrid vehicles
Symbol: Eignung für taxi vehicles
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 90º
Sealed maintenance-free AGM battery | electrolyte absorbed in glass fibre mats | wet charged

intAct Start-Stop-Power AGM Start. Stop. Keep charging.

Enables a high number of engine starts and supplies all consumers when the motor stops. Perfect for taxis, medium and high-end cars, SUVs and trucks with start-stop systems and micro-hybrids with brake energy recovery (recuperation).

Our recommendation for start-stop vehicles with high energy demand and micro-hybrids with recuperation.

Features

  • Quick charging.

    Due to AGM technology, this battery charges particularly quickly. Ideal for cabs, also good for recuperation.
    Your advantage: This battery recharges quickly, even on short trips.

  • Frequent start

    A special grid shape provides
    higher cycle stability than a standard starter battery.
    **Your advantage: withstands the short charging times and frequent engine starts better than standard starter battery.

  • Much starting power

    As AGM with large reaction surface on the glass fiber fleece, this battery has a high starting power even partially discharged.
    Your advantage: Also suitable for vehicles with high power requirements (e.g. those with auxiliary heating).

Characteristics

  • Excellent starting characteristics even at low charge level.
  • Higher cycle stability and cold start performance than a standard starter battery of same case size. Resulting in a longer life expectancy.
  • Fantastic recharging behaviour in the partial charge range.
  • Also for vehicles with high energy requirements and/or a lot of additional equipment.
  • Double lid with safety valve (VRLA), gas recombination and backfire protection. Leak-proof.
  • Sealed AGM battery with lead-calcium-tin grids.
  • For start-stop vehicles and micro-hybrids with brake energy recovery (recuperation) and fuel-saving systems.
  • Absolutely maintenance-free battery, where refilling is neither possible nor necessary.
  • Can also be installed at an angle, as the electrolyte is absorbed in glass fibre mats and the battery is tightly sealed.
  • Wet charged. Ready to use.
Recycling efficiency 95 %
Start-Stop
OEM quality
Maximum tipping angle 90º

All Types

intAct Start-Stop-Power AGM

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
AGM50SSi1250 AH (c20)800 A (EN)26017320611more
product image Starter Battery intAct Start-Stop-Power AGM AGM50SS

AGM50SS

Japan-Code:{jpn}

AGM50SS

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:50 AH (c20)
Base plate:B07
Schema Bodenleiste B07Schema Bodenleiste B07
Cold Cranking Ampere:800 A (EN)
Size:260 x 173 x 206 mm
Schema Batteriekasten T12

Kasten: T12
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM60SSi1260 AH (c20)680 A (EN)24217519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM60SS

AGM60SS

Japan-Code:{jpn}

AGM60SS

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:60 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:680 A (EN)
Size:242 x 175 x 190 mm
Schema Batteriekasten L02

Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM70SSi1270 AH (c20)760 A (EN)27817519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM70SS

AGM70SS

Japan-Code:{jpn}

AGM70SS

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:70 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:760 A (EN)
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM80SSi1280 AH (c20)800 A (EN)31517519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM80SS

AGM80SS

Japan-Code:{jpn}

AGM80SS

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:80 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:800 A (EN)
Size:315 x 175 x 190 mm
Schema Batteriekasten L04

Kasten: L04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM95SSi1295 AH (c20)850 A (EN)35317519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM95SS

AGM95SS

Japan-Code:{jpn}

AGM95SS

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:95 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:850 A (EN)
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM105SSi12105 AH (c20)950 A (EN)39417519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM105SS

AGM105SS

Japan-Code:{jpn}

AGM105SS

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:105 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:950 A (EN)
Size:394 x 175 x 190 mm
Schema Batteriekasten L06

Kasten: L06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
What is an AGM battery?
ABSOLUTELY MAINTENANCE-FREE
LEAK PROOF
DOUBLE LID WITH LABYRINTH
FIBERGLASS FLEECE
Do I need a start-stop battery or a normal one?
In start-stop vehicles, the engine stops every time the vehicle is in neutral. This saves petrol and reduces air pollution. However, this means an extremely high load for the battery. It has to start much more often, i.e. deliver high currents, than a …
Do I need an EFB or AGM start-stop battery?
If an EFB start-stop battery is installed at the factory, it can be replaced again with an EFB start-stop battery. An upgrade to AGM is always possible. If an AGM start-stop battery is installed at the factory, it may only be replaced with an AGM start-stop …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does absolutely maintenance-free mean?
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains …
Why does this battery have such a good current draw?
Due to the AGM technology, this battery absorbs the current particularly well, i.e. it recharges faster than a conventional wet battery and you can charge it with a higher charging current or a more powerful charger, like the ? This characteristic comes …
What are start-stop batteries?
The EFB (Enhanced Flooded Battery) was developed for start-stop vehicles. This further development of the wet battery is significantly more cycle resistant, like the intAct Start-Stop-Power EFB. Because of the good current reserve, AGM batteries are also …
Dimensions before starting power
First of all, a battery must fit in your vehicle or machine. Check the dimensions of your old battery or the available space in the battery compartment of your vehicle. The placement of the terminals, i.e. where exactly the positive and negative terminals …
What the cold start performance says
Starter batteries primarily have to start the vehicle. To do this, they must deliver as much current as possible during the starting process, so the battery's high-current characteristics are important. The cold cranking amps (CCA) value provides information …
Always choose a battery that matches the load
Depending on the type of battery, it is designed for certain loads: Starter batteries must deliver as much current as possible during the starting process. The cold start current, measured in CCA, is informative here and shows how much starting power …
What are truck batteries
Batteries in trucks, commercial vehicles, agricultural machines and buses have to be vibration resistant due to engine vibrations. Our truck batteries in SHD versions are vibration resistant according to V3, like intAct Start-Power NG Truck, or V4, like …
What is a back-up battery?
In some cars, so many consumers are installed from the outset that it would overload the starter battery to supply them. This is where so-called back-up batteries are used. If your car is equipped with a back-up battery, you should replace it again with …
Safety instructions for handling acid
Battery acid consists partly of sulphuric acid, which is highly corrosive. It attacks your skin, textiles and even metal. Put on protective clothing! So always wear gloves, safety glasses and possibly an acid-proof apron when handling batteries. Choose …
Pay attention to the state of charge
We recommend: Check the charge level every 2 - 3 months if ... ... the vehicle is often left unused. ... you drive a lot of short distances. ... many consumers are installed. ... it is cold. ... in start-stop systems the engine does not switch off as …
Always choose the right battery for the application
When choosing a battery, it basically depends on what it is to be used for. The most important distinction is between starter batteries, including motorcycle batteries, and cyclic batteries such as traction or supply batteries. Starter batteries, including …
Avoid corrosion
The plates in a battery will corrode if they are not completely covered by battery water. Reasons for corrosion Sealing damaged before filling in dry pre-charged batteries Closed, low-maintenance batteries such as the intAct Bike-Power Classic are dry …
For plugs: Simply open them and look inside.
Low maintenance batteries have a distinct advantage: if something is wrong, you can open them and look inside. What you see will give you some clues. Warning: You can tell if the battery can be opened by the individual plugs on the top. Often these lead-acid …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.

For which applications is the intAct Start-Stop-Power AGM suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van
Symbol WohnmobileWohnmobile
Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge
Symbol MarineMarine
Boats, ships, yachts
Symbol hybrid vehicleshybrid vehicles
hybrid vehicles, hybrid cars, hybrid electric vehicles, hybrid electric vehicles
Symbol taxi vehiclestaxi vehicles
Start-Stop batteries for taxi vehicles with increased engine starts and long supply of the consumers when the engine is not running.